Vertical Multistage Pump

  • EVP

    0 out of 5
    • Application
      Water supply: Pressure boosting for main pipes and high-rise buildings
      Industrial pressure boosting:Water system,cleaning system,high pressure
      washing system and firefighting system
      Pressure boosting for pressure tank, sprinkling irrigation and trichling irrigation
      ir conditioner, cooling system and industrial cleaning
    • Features
      Economic vertical multistage pumps
      Applicable for a wide scope of different temperatures,flow rates and pressure ranges
      Water inlet and outlet can be rotated for proper assembly in accordance with
      installation requirement
      Easy installation and maintenance
      Advanced hydraulic model design,featuring stable operation and high efficiency
      Cast iron water inlet and outlet with special anti-rust treatment
      High-strength engineering plastic flow passage components
      Reliable stainless steel welded shaft
    • Working Conditions
      Liquid temperature:+ 5℃~60℃
      Maximum ambient temperature:+ 40℃
      Maximum pressure: 15 bar
      Altitude:up to 1000 m
  • EVS

    0 out of 5
    • Application
      Suitable for transferring liquids of low viscosity,non-inflammable and
      non-explosive,not containing solid particles or fibers.
      Water supply%drainage for high-rise buildings,filtration and transfer
      at waterworks,pressure boosting in main pipe.
      Washing and cleaning systems,boiler feeding,cooling water
      circulation,water treatment systems,auxiliary system,support equipemt.
      Ultra-filtration systems,reverse-osmosis systems.
    • Pump
      AISI304 Impeller,diffuser,barrel
      Stainless steel welded shaft
      Liquid temperature range:+ 4℃~+ 60℃
      Cast iron water inlet and outlet with special anti-rust treatment
      Liquid PH value:6.5-8.5
      Max.operation pressure:15 bar
      Altitude:up to 1000 m
      C&U bearing
    • Motor
      Motor with copper winding
      Insulation class: F
      Protection class:IP55
      Max.ambient temperature:40°C
  • LVS/LVR

    0 out of 5
    • Application
      Suitable for transferring liquids of low viscosity, non-
      inflammable and non-explosive, not containing solid
      particles or fibers.
      Water supply&drainage for high-rise buildings,
      filtration and transfer at waterworks, pressure boosting
      in main pipe.
      Washing and cleaning systems, boiler feeding, cooling
      water circulation, water treatment systems, auxiliary
      system, support equipment.
      Ultra-filtration systems,reverse-osmosis systems,distillation
      systems, separators, swimming pools.
      Agricultural irrigation: sprinkler irrigation, drip-feed irrigation.
      Food&beverage industry.
      Fire-fighting system.
    • Operating Conditions
      Low viscosity, non-inflammable and non-explosive liquids
      not containing solid particles or fibers. The liquids must not
      chemically attack the pump materials. When pumping liquids
      with a density or viscosity is higher than that of water, a motor
      with a higher output power rating shall be used.
      Liquid temperature:-20℃〜+ 120℃
      Flow ranges: 0.7-240 m3/h
      Liquid pH value:4-10
      Max.ambient temperature:+ 40℃
      Max. operation pressure: 33 bar
      Altitude: up to 1000 m
    • Motor
      IE 2 motor (IE 3 motor optional)
      Totally enclosed&fan-cooled
      Protection class:IP55
      Standard voltage :50Hz 1×220V / 3×380V
    • Ambient Temperature
      Max.ambient temperature:+ 40℃.Ambient temperature
      above 40℃or installation at altitude of more than 1000 meters
      above sea level require the use of an oversize motor. Because
      of low air density and poor cooling effects, the motor output
      power P2 will be decreased. See the picture.
      In such cases, it may be necessary to use a motor with a higher
      output power rating.
  • LPP

    0 out of 5
    • Application
      HVAC: Circulation of hot water, boiler mix-flow, temperature mix-flow,
      intermittent heat supply, etc.
      Air conditioning system: Cooling water circulation.
      Water supply system: Filtration and transfer at waterworks;
      Pressure boosting in main pipe.
      Industrial applications: Washing& cleaning systems, boiler feeding,
      cooling water circulation, water treatment systems, and auxiliary
      systems.
      Fire-fighting system.
    • Pump
      Flow: up to 760 m3/h
      Head: up to 85 m
      Power range: 0.37 -132 kW
      Liquid temperature:0°C-+90°C
      Max ambient temperature:+ 40°C
      Max operation pressure: 16 bar
      Altitude: up to 1000 m
    • Motor
      Closed construction
      Insulation class:F
      Protection class: IP 55
      IE 2 motor as standard.IE 3 motor is available on request
    • Flange
      EN 1092 and DIN 2576 standard
    • Ambient Temperature
      Max. Ambient temperature:+40°C.Ambient temperature above40°C,or
      installation at altitude of more than 1000 m above sea level, require the
      use of an oversize motor. Because of low air density and poor cooling
      effects, the motor output power P2 will be decreased. See the picture.
      For example, when the pump is installed at altitude of more than 3500 m
      above sea level,P2 will be decrease to 88%.when the ambient
      temperature is 70°C,P2 will be decreased to 78%.