EVP
- Application
Water supply: Pressure boosting for main pipes and high-rise buildings
Industrial pressure boosting:Water system,cleaning system,high pressure
washing system and firefighting system
Pressure boosting for pressure tank, sprinkling irrigation and trichling irrigation
ir conditioner, cooling system and industrial cleaning
- Features
Economic vertical multistage pumps
Applicable for a wide scope of different temperatures,flow rates and pressure ranges
Water inlet and outlet can be rotated for proper assembly in accordance with
installation requirement
Easy installation and maintenance
Advanced hydraulic model design,featuring stable operation and high efficiency
Cast iron water inlet and outlet with special anti-rust treatment
High-strength engineering plastic flow passage components
Reliable stainless steel welded shaft
- Working Conditions
Liquid temperature:+ 5℃~60℃
Maximum ambient temperature:+ 40℃
Maximum pressure: 15 bar
Altitude:up to 1000 m
-
EVS
- Application
Suitable for transferring liquids of low viscosity,non-inflammable and
non-explosive,not containing solid particles or fibers.
Water supply%drainage for high-rise buildings,filtration and transfer
at waterworks,pressure boosting in main pipe.
Washing and cleaning systems,boiler feeding,cooling water
circulation,water treatment systems,auxiliary system,support equipemt.
Ultra-filtration systems,reverse-osmosis systems.
- Pump
AISI304 Impeller,diffuser,barrel
Stainless steel welded shaft
Liquid temperature range:+ 4℃~+ 60℃
Cast iron water inlet and outlet with special anti-rust treatment
Liquid PH value:6.5-8.5
Max.operation pressure:15 bar
Altitude:up to 1000 m
C&U bearing
- Motor
Motor with copper winding
Insulation class: F
Protection class:IP55
Max.ambient temperature:40°C
-
LVS/LVR
- Application
Suitable for transferring liquids of low viscosity, non-
inflammable and non-explosive, not containing solid
particles or fibers.
Water supply&drainage for high-rise buildings,
filtration and transfer at waterworks, pressure boosting
in main pipe.
Washing and cleaning systems, boiler feeding, cooling
water circulation, water treatment systems, auxiliary
system, support equipment.
Ultra-filtration systems,reverse-osmosis systems,distillation
systems, separators, swimming pools.
Agricultural irrigation: sprinkler irrigation, drip-feed irrigation.
Food&beverage industry.
Fire-fighting system.
- Operating Conditions
Low viscosity, non-inflammable and non-explosive liquids
not containing solid particles or fibers. The liquids must not
chemically attack the pump materials. When pumping liquids
with a density or viscosity is higher than that of water, a motor
with a higher output power rating shall be used.
Liquid temperature:-20℃〜+ 120℃
Flow ranges: 0.7-240 m3/h
Liquid pH value:4-10
Max.ambient temperature:+ 40℃
Max. operation pressure: 33 bar
Altitude: up to 1000 m
- Motor
IE 2 motor (IE 3 motor optional)
Totally enclosed&fan-cooled
Protection class:IP55
Standard voltage :50Hz 1×220V / 3×380V
- Ambient Temperature
Max.ambient temperature:+ 40℃.Ambient temperature
above 40℃or installation at altitude of more than 1000 meters
above sea level require the use of an oversize motor. Because
of low air density and poor cooling effects, the motor output
power P2 will be decreased. See the picture.
In such cases, it may be necessary to use a motor with a higher
output power rating.
-
LPP
- Application
HVAC: Circulation of hot water, boiler mix-flow, temperature mix-flow,
intermittent heat supply, etc.
Air conditioning system: Cooling water circulation.
Water supply system: Filtration and transfer at waterworks;
Pressure boosting in main pipe.
Industrial applications: Washing& cleaning systems, boiler feeding,
cooling water circulation, water treatment systems, and auxiliary
systems.
Fire-fighting system.
- Pump
Flow: up to 760 m3/h
Head: up to 85 m
Power range: 0.37 -132 kW
Liquid temperature:0°C-+90°C
Max ambient temperature:+ 40°C
Max operation pressure: 16 bar
Altitude: up to 1000 m
- Motor
Closed construction
Insulation class:F
Protection class: IP 55
IE 2 motor as standard.IE 3 motor is available on request
- Flange
EN 1092 and DIN 2576 standard
- Ambient Temperature
Max. Ambient temperature:+40°C.Ambient temperature above40°C,or
installation at altitude of more than 1000 m above sea level, require the
use of an oversize motor. Because of low air density and poor cooling
effects, the motor output power P2 will be decreased. See the picture.
For example, when the pump is installed at altitude of more than 3500 m
above sea level,P2 will be decrease to 88%.when the ambient
temperature is 70°C,P2 will be decreased to 78%.